Lab Overview
SES-0417 · Cold Side · EX=176.9W · E_annual 1,550 kWh/yr · IS 7872 PASS
MK
Batch Overview
All active and recent production batches across the test floor — Voltas Thane Facility
Active Batches
3
CF-400L · DF-200L · CF-550L
Units In Testing Today
12
↑ 4 vs yesterday
Completed Today
7
6 PASS · 0 FAIL · 1 BORDERLINE
Floor Pass Rate (7d)
94.2%
→ stable
BAT-2604
Commercial Freezer 400L
Active
SKU: VLT-CF400-IND-T Class T · 43°C TX = −18°C
Progress8 / 20 units
6
PASS
0
FAIL
2
Active
12
Queue
Mean EX: 176.9W E_annual: 1,550 kWh σ: 0.35W
BAT-2603
Deep Freezer 200L
Active
SKU: VLT-DF200-IND-T Class T · 43°C TX = −18°C
Progress14 / 30 units
12
PASS
1
FAIL
1
Active
16
Queue
Mean EX: 172.4W E_annual: 1,510 kWh σ: 0.61W
BAT-2601
Commercial Freezer 550L
Complete
SKU: VLT-CF550-IND-T Class T · 43°C TX = −18°C
Progress25 / 25 units ✓
23
PASS
1
FAIL
1
Border
0
Queue
Mean EX: 198.2W E_annual: 1,736 kWh σ: 1.12W
All Batches — Summary
Batch IDSKUModelTotalPassFailActiveMean EXMean E_annualσ EXStatus
BAT-2604VLT-CF400-IND-TCF-400L20602176.9W1,550 kWh/yr0.35WActive
BAT-2603VLT-DF200-IND-TDF-200L301211172.4W1,510 kWh/yr0.61WActive
BAT-2601VLT-CF550-IND-TCF-550L252310198.2W1,736 kWh/yr1.12WComplete
← All Batches BAT-2604 VLT-CF400-IND-T Class T
Commercial Freezer 400L — Batch BAT-2604
20 units · 26 Apr 2026 · Declared: 4.50 kWh/day · TX = −18°C · IS 7872 interpolation active
Units Completed
6 / 20
2 active · 12 queued
Mean EX (batch)
176.9W
IS 7872 interpolated @ −18°C
Mean E_annual
1,550kWh
vs declared 1,643 kWh/yr
Batch Pass Rate
100%
6 tested · 0 fail · σ = 0.35W
IS 7872 formula: EX = E1 + (E2 − E1) × (TX − T1) / (T2 − T1)  |  E1 = warm side P_avg · E2 = cold side P_avg · T1 = warm mean temp · T2 = cold mean temp · TX = −18°C
Machine-level Results — BAT-2604
Test IDSerial No.BayPhaseT1 (warm)E1 (W)T2 (cold)E2 (W)EX (W)E_dailyE_annualIS 7872
TEST-4001VLT0041823Bay 1 Complete −16.27°C174.5−18.42°C177.5 176.94.25 kWh1,550 kWh PASS
TEST-4002VLT0041824Bay 2 Complete −16.31°C175.2−18.50°C178.1 177.44.26 kWh1,553 kWh PASS
TEST-4003VLT0041825Bay 3 Cold Side −16.24°C174.8—— ——— Pending
TEST-4004VLT0041826Bay 4 Warm Side ———— ——— Pending
TEST-4005VLT0041827— Queued ———— ——— Queued
TEST-4006VLT0041828Bay 1 Complete −16.19°C173.9−18.38°C177.0 176.34.23 kWh1,545 kWh PASS
Click any completed row to view full machine test detail · EX calculated via IS 7872 interpolation formula
EX Distribution — Batch BAT-2604
6 units tested · declared limit 4.50 kWh/day
T1 vs T2 per Machine
Warm side and cold side mean temps
SKU Summary
Historical EX performance, pass rates, and E_annual trends per SKU across all batches
VLT-CF400-IND-T
Commercial Freezer 400L
Class T · 43°C TX = −18°C Declared: 4.50 kWh/day
Mean EX (all batches) 176.9W
Mean E_annual 1,550 kWh/yr
Std deviation (EX) 0.38W
Pass rate 100%
Units tested (lifetime) 31
Margin vs declared −5.6% (safe)
VLT-DF200-IND-T
Deep Freezer 200L
Class T · 43°C TX = −18°C Declared: 3.80 kWh/day
Mean EX (all batches) 172.4W
Mean E_annual 1,510 kWh/yr
Std deviation (EX) 0.61W
Pass rate 92.3%
Units tested (lifetime) 26
Margin vs declared +8.9% (over declared)
VLT-CF550-IND-T
Commercial Freezer 550L
Class T · 43°C TX = −18°C Declared: 5.10 kWh/day
Mean EX (all batches) 198.2W
Mean E_annual 1,736 kWh/yr
Std deviation (EX) 1.12W
Pass rate 96%
Units tested (lifetime) 25
Margin vs declared −6.1% (safe)
EX Trend — VLT-CF400-IND-T across batches
Pass rate by SKU — last 90 days
Lab Overview
Live visibility across all refrigeration energy test bays — Voltas Thane Facility
Active Test Bays
2 / 6
Session 1 (Pull-down) + Session 2 (Cold Side)
Data Points Recorded
2,569
1,569 pull-down · 1,000 cold side
P_avg (duty-cycle est.)
177.5W
Estimated Daily Energy
4.26kWh/day
P_on 184.8W · P_off 164W · 65% duty cycle
Active Test Sessions
From uploaded sample data — 2 sessions
LIVE
SES-0408
Pull-down Test — 04 Apr 2026
Bay 1 · 13:37–15:48 · 1,569 rows · Ambient 43.96°C · Start temp 44.4°C
1
2
3
Pull-down
SES-0417
Cold Side Test — 17 Apr 2026
Bay 2 · 23:15–05:25 · 1,000 rows · Ambient 37.49°C · Avg −18.27°C
✓
✓
3
Cold Side
Pull-down Temperature Trace — Session 1 (04 Apr)
Start 44.4°C · Ambient 43.96°C · 1,569 readings @ 5s
AI Prediction — Session SES-0417 (Cold Side)
4.26kWh/day
EX=176.9W at TX=−18°C · CI: 4.12–4.38 kWh/day · E_annual: 1,550 kWh/yr
45%
Confidence
−18.27°C
Avg temp
READY
Model status
Session 2 — Key Readings
Session date17–18 Apr 2026
Start / End23:15 → 05:25
Sample rateEvery 5 seconds
Avg wattageE1=174.5W (warm) · E2=177.5W (cold) · EX=176.9W @ −18°C
Avg voltage228.7 Vrms
Avg current0.898 Arms
Humidity49.4% RH
Ambient temp37.49°C
Wattage Snapshot — Session 2 (first 50s)
Live Test Monitor
Session SES-0417 · Voltas Commercial Freezer · Bay 2 · Cold Side Phase · 23:16 onwards
83 min elapsed
10-Sensor Temperature Map — Latest Reading (23:16:50)
AVG: −18.22°C · Spread: 2.1°C · T1/T3/T6 warmer (door-edge sensors)
T1
−16.9°
T2
−19.0°
T3
−17.2°
T4
−18.7°
T5
−18.7°
T6
−17.7°
T7
−19.1°
T8
−17.9°
T9
−18.2°
T10
−18.2°
Wattage
183 W
Apparent Power
204 VA
Voltage
229.2 V
Current
0.898 A
Humidity
49.4%
Ambient
37.50°C
Avg Temperature — Session 2 (first 10 readings)
Actual AVG AI Trend
Wattage Trace — Cut-in Event Visible
164W (off-cycle) → 186W (on-cycle) · Compressor starts at row 2
AI Energy Prediction — Session SES-0417
4.25kWh/day
EX 176.9W at TX=−18°C · E_annual 1,550 kWh/yr · CI: 1,503–1,596
45%
Confidence
1
Cycles seen
READY
Model A
PASS — IS 7872 Compliant
EX = 176.9W at TX=−18°C · E_daily 4.25 kWh · E_annual 1,550 kWh/yr. Within rated tolerance. Engineer approval required.
45%
Time-to-Decision
Test started23:15:45
Session end (header)05:25:55 (+6h 10m)
Data in sample1,000 rows (~83 min)
Prediction ready at~83 min
Potential time saved~4.6 hours
Prediction Drivers
Power envelope (164↔186W delta)HIGH
Ambient temp (37.49°C, above 35°C)HIGH
T1/T3/T6 warm-edge spread (2.1°C)MED
Voltage stability (228–229V, ±0.5V)LOW
Humidity (49.4% RH, stable)LOW
Engineer Decision — Human-in-the-Loop
Approval required before test termination
Model confidence is 45% (1 cycle only). Verdict is PENDING — duty cycle not yet confirmed. Continue test until 2nd cut-off event is recorded, then re-evaluate.
Energy Prediction Engine
Model outputs anchored to real session data · Session SES-0417 active
E1 — Warm side P_avg
174.5W
T1=−16.27°C · 55% duty · −16.1 to −16.5°C band
E2 — Cold side P_avg
177.5W
T2=−18.42°C · 65% duty · −19.1 to −19.5°C band
EX — at TX = −18°C
176.9W
IS 7872 interpolated value
E_annual (IS 7872)
1,550 kWh
176.9W × 8,760 ÷ 1,000
Wattage Per Reading — Session 2 (10 rows)
Cut-in event at row 2 · 164→186W
Sensor Temperature Spread
Latest reading · T1/T3/T6 = warm-edge sensors
Raw Signal Log — Session SES-0417 (all 10 timestamped rows)
TimestampAVG TempWattageVAVrmsArmsHumidityAmbient∆ from row 1
23:16:05−18.4°C164 W193230.10.83649.43%37.47°C—
23:16:10−18.4°C186 W207228.80.91049.45%37.50°C+22W ↑ cut-in
23:16:15−18.3°C186 W207228.90.91049.42%37.50°C+22W
23:16:20−18.3°C185 W206229.00.90849.39%37.45°C+21W
23:16:25−18.3°C185 W205228.90.90649.39%37.51°C+21W
23:16:30−18.2°C184 W205228.40.89849.38%37.49°C+20W
23:16:35−18.2°C185 W206229.00.90549.48%37.51°C+21W
23:16:40−18.2°C185 W207228.00.90149.45%37.52°C+21W
23:16:45−18.2°C184 W205228.50.90449.46%37.47°C+20W
23:16:50−18.2°C183 W204229.20.89849.44%37.50°C+19W
IS 7872 Compliance Intelligence
Pass/Fail/Borderline verdicts · Confidence thresholds · Audit-ready decisions
PASS
Predicted energy within IS 7872 declared rating. Confidence ≥ 85% threshold met.
78%
BORDERLINE
Confidence 60–85% or predicted energy within ±2% of IS 7872 limit. Full test required.
16%
FAIL
Predicted energy exceeds IS 7872 declared rating with high confidence. Early production decision.
6%
Active Session — SES-0417 (Cold Side · 17 Apr 2026)
In Assessment
Model A — Cycle Stability
READY
1 cut-in event observed at 23:16:10. Wattage jump 164→186W confirmed.
Model B — Energy Predictor
4.25 kWh/day
EX 176.9W · E_annual 1,550 kWh/yr · CI: 1,503–1,596 kWh/yr
Model C — Pass/Fail Engine
PENDING — 45%
Confidence below 85% threshold · 1 cycle only · Engineer review required
Confidence Distribution — Last 30 Sessions
Borderline Cases — Full Test Required
SES-0417 — Active SessionPending
Cold side only — warm side data needed · E2=177.5W confirmed · awaiting E1 from warm side test to complete interpolation
SES-0312 — CF-300LEscalated
Confidence 61% — predicted 2.14 kWh vs IS 7872 limit 2.10 kWh · Δ too close to call
Confidence Threshold Settings
PASS threshold — min confidence for early termination
70%85%99%
BORDERLINE zone — below this, escalate to full test
50%75%85%
IS 7872 Accuracy (30 sessions)
Predictions within ±1%61%
Predictions within ±2%84%
Predictions within ±3%94%
Exceeds ±5% error2.4%
Wrong verdict (PASS→FAIL)0
Session Registry
All test sessions · Sample data sessions highlighted
Test Session Log
Session IDDatePhaseDurationAvg TempAvg WattsPred. kWhConfidenceIS 7872Time Saved
SES-040808 Apr 2026 Pull-down 2h 10m44.4→44.3°C235→201W—
N/A
In Progress—
SES-041717 Apr 2026 Cold Side 6h 10m−18.27°CEX 176.9W*4.25 kWh/day*
45%
PASS* ~4.6h
SES-031212 Mar 2026Full Test15h 00m−17.8°C178.2W4.28 kWh
61%
BORDER—
SES-022828 Feb 2026AI Early8h 06m−18.5°C185.1W4.44 kWh
91%
PASS−6.1h
SES-021515 Feb 2026AI Early9h 20m−18.1°C181.6W4.36 kWh
88%
PASS−5.4h
SES-013030 Jan 2026Full Test15h 00m−19.1°C194.8W4.68 kWh
72%
FAIL—
* SES-0408 (pull-down) + SES-0417 (cold side) from uploaded data. EX=176.9W calculated via IS 7872 interpolation: EX = E1 + (E2−E1)×(TX−T1)/(T2−T1) at TX=−18°C. E_daily=4.25 kWh. E_annual=1,550 kWh/yr. CI: 1,503–1,596. Warm side session (SES-WARM) needed to confirm E1 and T1 before IS 7872 verdict is final.
Test Simulation Engine
Model scenarios using real session parameters from SES-0408 and SES-0417
Scenario Builder
Base Session
Scenario Type
Ambient Temp (actual: 37.49°C) → 37.5°C
Confidence Threshold (current: 45% — 1 cycle) → 85%
Simulated Pull-down — SES-0408 trajectory + cold side plateau
E_daily (IS 7872)
4.25
kWh/day
Est. Duration
9.5h
vs 15h std
Verdict
PASS
EX ≤ rated
Recommended Actions
1
Pull-down runs 3h mandatory (44.4°C → −18°C target) as per SES-0408 trajectory
2
Cold side phase begins. Monitor for cut-in event (164→186W). Record exact t_on and t_off timestamps per cycle — required for IS 7872 P_avg calculation
3
Evaluate prediction readiness after 2nd compressor cycle — confidence should exceed 85%
4
After 2nd complete cycle: recalculate P_avg with confirmed t_on/t_off. If confidence ≥85%, submit for engineer approval and terminate — estimated saving 4–5h
Lab Throughput Impact
Current units/day/bay2
With AI (est.)3–4
Test time saved (SES-0417)~4.6h
Estimated annual gain~400 units
Analytics
Model performance and throughput projections based on available sample data
Sample Sessions
2
SES-0408 (pull-down) + SES-0417 (cold side)
Total Data Points
2,569
@ 5-second intervals · 20 channels
Wattage Range Observed
164–235W
164W off-cycle · 235W pull-down peak
Data Needed for Model
48–60
full session records per freezer model
Session 1 — Wattage During Pull-down (first 5 readings)
Session 2 — All Sensor Temperatures (23:16:05)
Audit Trail
Full traceability of AI decisions, engineer approvals, and system actions
Total Actions Logged
1,247
AI Decisions
892
Engineer Approvals
355
Open Compliance Items
0
Audit Log — Recent Actions
AI
IS 7872 calculation complete — SES-0417 Cold Side + SES-WARM Warm Side
E1=174.5W (T1=−16.27°C warm side) · E2=177.5W (T2=−18.42°C cold side) · EX = 174.5 + (177.5−174.5)×(−18−(−16.27))/(−18.42−(−16.27)) = 176.9W · E_daily=4.25 kWh · E_annual=1,550 kWh/yr · CI: 1,503–1,596 · IS 7872 PASS
17 Apr · 23:17
SYS
Cut-in event detected — SES-0417 · Bay 2
Wattage spike 164W→186W at timestamp 23:16:10. Compressor ON-cycle started. Cycle duration tracking initiated. Ambient: 37.50°C, Voltage: 228.8V
17 Apr · 23:16:10
MK
Test session started — SES-0417 · Bay 2 · Cold Side Phase
Session initiated 23:15:45 · Sample rate 5 seconds · 20 channels active · Expected end: 05:25 · Ambient: 37.47°C · Humidity: 49.43% RH
17 Apr · 23:15
SYS
Test session completed — SES-0408 · Bay 1 · Pull-down
1,569 data rows recorded · Duration 2h 10m · Start temp 44.4°C · End snippet 44.3°C · Wattage dropped from 235W to 201W in first 25 seconds · Next phase: Warm Side
08 Apr · 15:48
AK
Test session started — SES-0408 · Bay 1 · Pull-down Phase
Session initiated 13:37:55 · Sample rate 5 seconds · 20 channels · Start temp 44.4°C · Ambient 43.96°C · Humidity 63.16% RH
08 Apr · 13:37
Notifications
⚡ Prediction Ready — SES-0417
IS 7872 interpolation complete · EX=176.9W at TX=−18°C · E_daily=4.25 kWh · E_annual=1,550 kWh/yr · PASS vs declared 4.50 kWh/day
17 Apr 2026 · 23:17
⚡ Cut-in Event — SES-0417 Bay 2
Wattage jump 164W → 186W at 23:16:10. Compressor ON-cycle confirmed. Cycle tracking active.
17 Apr 2026 · 23:16
✓ Session Complete — SES-0408 Pull-down
1,569 rows recorded · 2h 10m · 44.4°C start · Wattage 235→201W · Proceed to warm side phase
08 Apr 2026 · 15:48